Home Print this page Email this page Users Online: 119
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 

 Table of Contents  
ORIGINAL ARTICLE
Year : 2023  |  Volume : 13  |  Issue : 1  |  Page : 51-56

Effect of various volume syringes on solution delivery time using conventional irrigation technique in 0.04 tapered preparations of single straight root canals: An ex vivo study


1 Departments of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
2 Department of Endodontics, Faculty of Dentistry, Karabük University, Karabük, Turkiye
3 Department of Conservative Dentistry and Endodontics, SRM Dental College, SRM Institute of Science and Technology, Chennai, Tamil Nadu, India
4 Department of Prosthodontist and Oral Implantologist, Hyderabad, Telangana State, India
5 Telemedicine and Telepharmacy Centre, School of Medicinal and Health Product Sciences, University of Camerino, Camerino, Italy

Date of Submission19-Jan-2022
Date of Decision14-Jun-2022
Date of Acceptance15-Jun-2022
Date of Web Publication11-Jan-2023

Correspondence Address:
Dr. Sindhu Ramesh
Department of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, 162, Poonamallee High Road, Chennai - 600 077, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/sej.sej_15_22

Rights and Permissions
  Abstract 

Introduction: The important aspect of endodontic treatment is root canal irrigation. Although agitation systems proved to have enhanced irrigant wall interactions, syringe needle-based delivery systems still play a significant role during the preparatory phases of root canal treatment. The current study aimed to evaluate the time taken for the irrigant delivery during conventional syringe irrigation using different volume syringes in different root canal preparations.
Materials and Methods: Two hundred extracted single-rooted premolars with approximately round canals were randomly instrumented to preferred apical preparation sizes using 0.4 tapered Hyflex-CM rotary Ni-Ti instruments and randomly divided as follows: Group I, instrumentation to size 40, 0.04 taper (n = 50); Group II, instrumentation to size 30, 0.04 taper (n = 50); Group III, instrumentation to size 25, 0.04 taper (n = 50); and Group IV, instrumentation to size 20, 0.04 taper (n = 50). Fifty operators were chosen for the experimentation. They were asked to irrigate the prepared specimens using different volume syringes. The entire irrigant delivery time was recorded by a head nurse using a stopwatch, and the values were calibrated and statistically analyzed.
Results: Group I recorded significantly lesser time for irrigant delivery during manual syringe needle irrigation (P = 0.005) compared to other groups.
Conclusion: Irrigation delivery time was less in 40/0.04 taper preparations, using 1 ml volume syringes.

Keywords: Endodontics, irrigant, root canal preparation, rotary instrumentation, syringe needle


How to cite this article:
Teja KV, Ramesh S, Choudhari S, Özdemir O, Janani K, Jose J, Vasundhara KA, Battineni G. Effect of various volume syringes on solution delivery time using conventional irrigation technique in 0.04 tapered preparations of single straight root canals: An ex vivo study. Saudi Endod J 2023;13:51-6

How to cite this URL:
Teja KV, Ramesh S, Choudhari S, Özdemir O, Janani K, Jose J, Vasundhara KA, Battineni G. Effect of various volume syringes on solution delivery time using conventional irrigation technique in 0.04 tapered preparations of single straight root canals: An ex vivo study. Saudi Endod J [serial online] 2023 [cited 2023 Feb 3];13:51-6. Available from: https://www.saudiendodj.com/text.asp?2023/13/1/51/367514


  Introduction Top


Syringe needle irrigation is the most commonly employed technique during root canal irrigation.[1] Syringe needles of various designs have been introduced for irrigant delivery for conventional irrigation.[2] Especially, needles with side-vented channels dispense/irrigant through the most distal end or laterally[3] and tend to improve the hydrodynamic activation of the irrigant and reduce the chances of apical extrusion.[4] Various in vitro level-based computational fluid dynamic (CFD) analysis reports employ a flow rate of 0.26 ml/s,[5] for efficient irrigation. Clinically, it might not be possible to deliver 15.6 ml of irrigant consistently in all tapered root canals and by all operators.[6] It leads to the fatigue of the operator, if continuously; such a large volume of irrigant is delivered, within a short time.[7] Clinically, it is impossible to standardize the syringe needle irrigation. The previous report highlighted that the force of delivery of irrigant varies from operator to operator and gender wise and the clinician's experience wise too.[8]

Although the major factor that guards the efficacy of syringe needle irrigation (SNI) is the irrigant penetration and flushing action,[9] various other factors are also involved in improvising the efficacy of SNI. System of delivery,[10] volume of irrigant used[10] and the properties of the fluid used for irrigation,[11] needle choice, needle type,[12] and the insertion depth of the needle placed in root canal[13] have a major role during SNI.

A recent systematic review highlighted that needle placement, taper, and apical preparation sizes are considered the most efficient clinical factors safeguarding the syringe needle irrigation.[12] Literature from in vitro level-based studies still emphasizes the ambiguity of various preparation sizes on the irrigant delivery time.[12],[14] Literature is scarce on apical preparation size and taper of the root canal relative to simulated irrigant flow time.[15],[16] At an in vitro level, virtual-based CFD analysis states that increased taper and preparation sizes have a beneficial effect on reducing the simulated irrigation time.[15],[16] Although there is no clear-cut evidence on the exact taper and preparation size required to achieve the effective irrigant flow, root canal enlargement to a size larger than 25 appeared to improve the syringe needle irrigation.[16] Hence, the present study tried to assess the solution delivery time in optimally shaped root canals.

The other most important factor that is frequently neglected is the intrabarrel pressure that is developed in due course of root canal irrigation.[7] Especially, when finer needle diameters are considered, the intrabarrel pressure is increased.[8] Considering all these facts, the present study tried to assess the effect of root canal preparation size on the irrigant delivery time using different volume syringes for manual syringe needle irrigation.


  Materials and Methods Top


Teeth selection

The present study proposal was approved by the Institutional Review Board and Ethical Committee of Saveetha Dental College and Hospitals, India (SRB: SDC/ENDO-1703/20/455), and ethical consent was obtained from patients before extraction. Two hundred freshly extracted noncarious single-rooted human mandibular premolars undergoing therapeutic orthodontic extraction were collected for the study. Prior pulp sensibility testing was carried out using a cold test (Green-Endo-Ice; Hygienic Corp, Akron, OH, USA) and electric pulp testing (Kerr Analytic Technology Corp, Redmond, WA, USA) before anesthetic administration to confirm the actual status of the pulp. The inclusion criteria for teeth selection were single-rooted intact human mandibular premolars, and teeth with <5° of canal curvature, which was determined using an intraoral periapical radiograph using Schneider's classification,[17] teeth with mature apices were considered. Teeth with calcifications, curvatures >5°, immature apices, and teeth extracted for other reasons were excluded.

Specimen standardization

Immediately after extraction, the soft tissue attached to the tooth surface was curetted and the collected specimens were stored in 5% formalin (Ricca Chemicals, Fisher Scientific, Mumbai, India). After the specimen collection, multiple intraoral periapical radiographs were taken to confirm the single-root morphology.

Specimens were decoronated using a diamond disk mounted on a straight handpiece (Confident Dental Equipments Ltd., India) under adequate water coolant. The specimens were standardized such that the root length was 17 mm totally from a flat reference point to 1 mm short of the major apical foramen terminus. This was confirmed using a working length radiograph. The working length was established before the subjection of the teeth for cone-beam computed tomography (CBCT) imaging to standardize the length of extracted specimens. The patency of the canals was determined using K-files ISO #10 (Dentsply, Maillefer, Ballaigues, Switzerland). Only teeth whose canal width near the terminus was approximately compatible with ISO #15 K-file were included. Once this was confirmed, the teeth were subjected to CBCT imaging to ensure the canal shape.

Imaging

The specimens were imaged using Kodak 9000 CBCT device (Carestream Dental Kodak Systems, Rochester, NY) to identify the single-rooted teeth with a single canal. The resolution of the acquired images was around 0.076 mm, 70 kvp, and 6.3 ma, and field of views was adjusted to 18.4 cm × 20.6 cm with 10.8 s scan time. The scanned specimens were then transferred to DICOM software, where multiple topographic sections were analyzed to make three-dimensional volume reconstructions using GALILEOS Viewer software (version 1.9.5603.25515, Informer Technologies Inc., Los Angeles, USA) at coronal, middle, and apical third to confirm the canal shape from the reference point to the radiographic terminus. Canals confirmed to have an approximately round shape to the entire canal length were included [Figure 1].
Figure 1: The CBCT sections of (a) coronal, (b) middle, and (c) apical showing approximately round canals, CBCT: Cone-beam computed tomography

Click here to view


Root canal preparation

The specimens were randomly allocated into four groups according to the tapered preparation: Group I, canals were instrumented to size 40, 0.04 taper (n = 50); Group II, to size 30, 0.04 taper (n = 50); Group III, to size 25, 0.4 taper (n = 50); and Group IV, to size 20, 0.4 taper (n = 50)

Instrumentation of the standardized specimens was carried out using a single instrument according to the group allocated. Hyflex CM rotary files (Coltene/Whaledent Inc., USA) were used. The speed and the torque adjustments were as specified by the manufacturer. In due course of instrumentation, irrigation was carried out using 10 ml of 3% sodium hypochlorite (Parcan, Septodont, India) using a 30-gauge side-vented needle (NaviTip, Ultradent Products, South Jordan, UT, USA), placed 1 mm short of the apex. After completing instrumentation, irrigation was carried out using 5 ml of 3% sodium hypochlorite and 3 ml of ethylenediaminetetraacetic acid (MD Cleanser, Meta Biomed, India). The final rinse was carried out using distilled water and canals were dried with paper points. After the procedure was completed, one standardized root specimen from each group was embedded in a wax model containing four root canal-prepared teeth (one from each group). These wax models were assessed for the irrigant delivery time using manual syringe needles with different volume syringes (5 ml, 2.5 ml, and 1 ml).

A total of 50 operators participated in the present study, out of which 30 operators were postgraduates (conservative and endodontics) and 20 of them were experienced clinicians (conservative and endodontics). Each operator was provided with a wax model with one specimen from each group with different tapered preparations (as mentioned previously). The root canal irrigation procedure and the protocol followed were explained to each operator. The specimens were randomly distributed to operators using the opaque-sealed envelope technique. The intraexaminer and interexaminer reliabilities were assessed using Cohen's kappa statistics.

Irrigation protocol

Operators were asked to use a 31-gauge side-vented single-port syringe needle for root canal irrigation. Each operator was provided with 3-volume barrels corresponding to 5 ml, 2.5 ml, and 1 ml, filled with 1 ml of sodium hypochlorite in all the barrels. They were asked to irrigate the root canal-prepared specimens using corresponding barrel syringes continuously without any interference, and the stopwatch was calibrated by a head nurse, once the irrigation was initiated. They were instructed to keep the syringe 1 mm short of the apex and continuously irrigate by moving the needle in short vertical strokes of 2–3 mm amplitude. If any fatigues were elicited by an operator during irrigation, the readings were stopped and the values were not taken into consideration and they were asked to repeat the procedure once again. Each operator was asked to perform the procedure thrice for each tapered preparation and the mean value of all these three readings was taken into consideration. This was done to avoid taking single values, which might not translate into accurate recording. At the end of each reading, operators were provided with a new syringe and barrel to irrigate the prepared canals. The same procedure was continued using three different syringe barrels. First, they were instructed to carry out 5 ml volume irrigation and calibrate three readings and then followed by carrying the protocol using 2.5 and 1 ml syringe barrels, respectively. 10 min of a break was given before performing the procedure for the next reading. This was done to prevent any fatigue-related issues that might vary the results.

Statistical analysis

The collected data were analyzed with IBM SPSS statistics software 23.0 Version (IBM SPSS Predictive Analytics Community, Armonk, New York, USA), Multivariate analysis and two-way ANOVA with Bonferroni's post hoc test were used.


  Results Top


The mean, standard deviation, and one-way ANOVA comparison for 5 ml, 2.5 ml, and 1 ml in different groups are presented in [Table 1] and [Figure 2]. Experiences of the operators are presented in [Figure 3] and multiple comparison analysis is presented in [Table 2]. Both one-way ANOVA and Tukey's post hoc revealed a statistically significant difference in total irrigation time among the four groups (P = 0.005). Among all the groups compared, Group I showed significant results (P = 0.0005), as compared to the other three groups. The intraexaminer reliability was found to be between 0.86 and 0.94 and the interexaminer reliability was found to be 0.77.
Table 1: Two-way ANOVA comparing the mean solution delivery time on using 5 ml, 2.5 ml, and 1 ml syringe in different groups assessed

Click here to view
Figure 2: The mean solution delivery time between various groups and syringe

Click here to view
Figure 3: The experience of the operators selected

Click here to view
Table 2: Multiple comparison analysis on solution delivery time on using 5 ml, 2.5 ml, and 1 ml syringes in different groups assessed

Click here to view



  Discussion Top


The current study aimed at assessing the solution delivery time in different apical preparation sizes on different syringe barrels. When the preparation size was taken into consideration, 40/0.04 taper preparations required less time (P = 0.0005) as compared to the other groups, when 1 ml volume syringes were used for irrigation. The present study results were correlated with previous in vitro level-based CFD analysis reports, stating that increased preparation sizes are shown to decrease the simulated irrigation time.[15],[16]

In the current study, CBCT imaging was done to confirm the root canal morphology. Our work[18] based on CFD analysis has shown constant increased apical pressures in round root canal morphologies. Hence, we have selected round canals for the present study. Currently, there is an ambiguity in irrigant flow rates in lesser tapered preparations.[12] Therefore, in the current study, we have considered studying clinical solution delivery times in 4% tapered preparations.

The present study results proved that there was no significant difference in the mean irrigant delivery time among the experienced clinicians versus postgraduates. Although experienced clinicians felt delivered the irrigating solution with ease, there were statistically significant differences that were observed. Both females and males were selected equally in the present study, as previous literature states that the irrigant delivery time using a manual syringe needle also varies according to the force used during irrigation, which might be gender related too.[8] When considered, the other factor that plays an essential role in using side-vented needles for irrigation is the experience with usage of the needles for root canal irrigation. In considering this factor, operators were chosen in such a way that they had varying levels of skill. Postgraduates from 1st, 2nd, and 3rd years were selected, out of which 1st-year graduate students did not have any previous experience using the specific syringe and needle for root canal irrigation. Hence, maybe, the present study would be appropriate in including all groups of operators to avoid operator-related bias.

The results of the present study showed a positive correlation with the aim of the experiment. The current study focused on assessing the irrigant delivery time on using different volume syringes in different prepared root canal specimens, the study results proved lesser delivery times at greater preparation sizes on using lesser volume syringes, when used for root canal irrigation. Although in a true clinical scenario, it is not always possible to refill 1 ml syringes for root canal irrigation, 2.5 ml volume syringes tend to serve the purpose. However, when thin tapered canals are taken into account, to prevent operator fatigue and to maintain the optimal flow rates, 1 ml volume syringes serve the purpose.

When comparison of the present study results has to be considered, none of the previous study reports can be compared, as the protocol for the assessment of the present study is different from the previous CFD analysis-based reports.[6],[15],[19],[20],[21] Specifically when previous in vitro study results on solution delivery time are considered, irrigant delivery time increases on using thinner gauge needles on using higher volume syringes.[6],[8],[21] Our results agreed with the previous study reports, which assessed different variables with a similar study concept. A recent simulation-based study assessed irrigant delivery time using CFD analysis, whose results could not be clinically comparable as it was a simulation-based study.[14] The current study mainly focused not only on the delivery time but also on the operator variations clinically on using different volume syringes. The topic is clinically more relevant as compared to the previous publication. As Sujith et al.[14] highlighted the increased pressures in smaller tapers and sizes, we have decided to conduct this study on multiple operators. The study protocol and outcomes are different from the previous simulation-based studies, published to date.[12]

An in vivo study done by Gopikrishna et al.[22] evaluated the irrigant flow rates in prepared mesial canals (instrumented to size 30, taper 0.6) of mandibular molars using different gauge open or side-vented needles and concluded that needle gauges have a significant influence on endodontic irrigation outcomes. However, to increase the effectiveness of irrigating agents, especially at the apical third, it is not advisable to prepare larger shapes and tapered preparations.[22] In a clinical scenario, where we tend to encounter thin and narrow shaped canals with varied canal curvatures, such larger preparations tend to cause deviations in original canal shapes. Hence, assuming the concept of shaping optimal to achieve maximal efficiency of the irrigating agent delivered,[23],[24] the present study laid a unique way of assessment of different volume syringes on the irrigant delivery time in prepared canals.

However, the present study also has various limitations, which might not translate into a true clinical scenario. Although the current study was standardized, it included multiple operators, with different experience levels, genders, and age groups, which could have given some varied results. The other limitation was considering straight and single-rooted canals with minimal or no curvatures. Hence, future investigations are advised to be carried on using the same protocol, especially for the assessment of prepared curved canals, which would be much more appropriate. Future studies can also better concentrate on the irrigant delivery and replacements using activation devices.


  Conclusion Top


Within the limitations of the present study, it can be concluded that 40.04 taper preparations recorded the least irrigant delivery time when 1 ml syringes were used for irrigation.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
Willershausen I, Wolf TG, Schmidtmann I, Berger C, Ehlers V, Willershausen B, et al. Survey of root canal irrigating solutions used in dental practices within Germany. Int Endod J 2015;48:654-60.  Back to cited text no. 1
    
2.
Topçuoğlu HS, Topçuoğlu G, Arslan H. The effect of apical positive and negative pressure irrigation methods on postoperative pain in mandibular molar teeth with symptomatic irreversible pulpitis: A randomized clinical trial. J Endod 2018;44:1210-5.  Back to cited text no. 2
    
3.
Kahn FH, Rosenberg PA, Gliksberg J. An in vitro evaluation of the irrigating characteristics of ultrasonic and subsonic handpieces and irrigating needles and probes. J Endod 1995;21:277-80.  Back to cited text no. 3
    
4.
Hauser V, Braun A, Frentzen M. Penetration depth of a dye marker into dentine using a novel hydrodynamic system (RinsEndo). Int Endod J 2007;40:644-52.  Back to cited text no. 4
    
5.
Gopikrishna V, Pare S, Pradeep Kumar A, Lakshmi Narayanan L. Irrigation protocol among endodontic faculty and post-graduate students in dental colleges of India: A survey. J Conserv Dent 2013;16:394-8.  Back to cited text no. 5
[PUBMED]  [Full text]  
6.
Huang Q, Barnes JB, Schoeffel GJ, Fan B, Tay C, Bergeron BE, et al. Effect of canal anastomosis on periapical fluid pressure build-up during needle irrigation in single roots with double canals using a polycarbonate model. Sci Rep 2017;7:1582.  Back to cited text no. 6
    
7.
Teja KV, Ramesh S, Vasundhara KA, Janani KC, Jose J, Battineni G. A new innovative automated root canal device for syringe needle irrigation. J Taibah Univ Med Sci 2022;17:155-8.  Back to cited text no. 7
    
8.
Boutsioukis C, Lambrianidis T, Kastrinakis E, Bekiaroglou P. Measurement of pressure and flow rates during irrigation of a root canal ex vivo with three endodontic needles. Int Endod J 2007;40:504-13.  Back to cited text no. 8
    
9.
Dhaimy S, Imdary S, Dhoum S, Benkiran I, El Ouazzani A. Radiological evaluation of penetration of the irrigant according to three endodontic irrigation techniques. Int J Dent 2016;2016:3142742.  Back to cited text no. 9
    
10.
van der Sluis LW, Gambarini G, Wu MK, Wesselink PR. The influence of volume, type of irrigant and flushing method on removing artificially placed dentine debris from the apical root canal during passive ultrasonic irrigation. Int Endod J 2006;39:472-6.  Back to cited text no. 10
    
11.
Kandaswamy D, Venkateshbabu N. Root canal irrigants. J Conserv Dent 2010;13:256-64.  Back to cited text no. 11
[PUBMED]  [Full text]  
12.
Teja KV, Ramesh S, Battineni G, Vasundhara KA, Jose J, Janani K. The effect of various in-vitro and ex-vivo parameters on irrigant flow and apical pressure using manual syringe needle irrigation: Systematic review. Saudi Dent J 2022;34:87-99.  Back to cited text no. 12
    
13.
Mandorah A. Effect of irrigation needle depth in smear layer removal: Scanning electron microscope study. Saudi Endod J 2013;3:114.  Back to cited text no. 13
  [Full text]  
14.
Sujith IL, Teja KV, Ramesh S. Assessment of irrigant flow and apical pressure in simulated canals of single-rooted teeth with different root canal tapers and apical preparation sizes: An ex vivo study. J Conserv Dent 2021;24:314-22.  Back to cited text no. 14
  [Full text]  
15.
Boutsioukis C, Gogos C, Verhaagen B, Versluis M, Kastrinakis E, Van der Sluis LW. The effect of root canal taper on the irrigant flow: Evaluation using an unsteady computational fluid dynamics model. Int Endod J 2010;43:909-16.  Back to cited text no. 15
    
16.
Boutsioukis C, Gogos C, Verhaagen B, Versluis M, Kastrinakis E, Van der Sluis LW. The effect of apical preparation size on irrigant flow in root canals evaluated using an unsteady computational fluid dynamics model. Int Endod J 2010;43:874-81.  Back to cited text no. 16
    
17.
Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 1971;32:271-5.  Back to cited text no. 17
    
18.
Choudhari S, Teja KV, Ramesh S, Kumar R, Valletta A, Maglitto M. Computational fluid dynamic analysis on the induced apical pressures in simulated oval and irregular round canals: an ex-vivo study. Giornale Italiano di Endodonzia. 2021;36. http://dx.doi.org/10.32067/GIE.2022.36.02.12.  Back to cited text no. 18
    
19.
Falk KW, Sedgley CM. The influence of preparation size on the mechanical efficacy of root canal irrigation in vitro. J Endod 2005;31:742-5.  Back to cited text no. 19
    
20.
Khan S, Niu LN, Eid AA, Looney SW, Didato A, Roberts S, et al. Periapical pressures developed by nonbinding irrigation needles at various irrigation delivery rates. J Endod 2013;39:529-33.  Back to cited text no. 20
    
21.
Park E, Shen Y, Khakpour M, Haapasalo M. Apical pressure and extent of irrigant flow beyond the needle tip during positive-pressure irrigation in an in vitro root canal model. J Endod 2013;39:511-5.  Back to cited text no. 21
    
22.
Gopikrishna V, Sibi S, Archana D, Pradeep Kumar AR, Narayanan L. An in vivo assessment of the influence of needle gauges on endodontic irrigation flow rate. J Conserv Dent 2016;19:189-93.  Back to cited text no. 22
[PUBMED]  [Full text]  
23.
Ruddle CJ. Endodontic disinfection: Tsunami irrigation. Saudi Endod J 2015;5:1.  Back to cited text no. 23
  [Full text]  
24.
Teja KV, Ramesh S. Shape optimal and clean more. Saudi Endod J 2019;9:235.  Back to cited text no. 24
  [Full text]  


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1], [Table 2]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Materials and Me...
Results
Discussion
Conclusion
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed274    
    Printed0    
    Emailed0    
    PDF Downloaded32    
    Comments [Add]    